Starting Equipment

During the early electrification of society, electricity was used in a variety of areas, with lighting being one example. A significant change took place in industry, where the use of electricity to power machines offered considerable advantages over steam engines and other mechanical drive systems. A current problem, one that even today’s machine manufacturers grapple with, is the high energy consumption during startup. Consequently, several methods have been developed over the years to start electric pumps, machines, and other equipment using so-called “starters.”

Certified Solutions

Elektromontage We have extensive experience in the design and manufacture of starting equipment and motor control centers for various applications, ranging from small pumps rated at a few kW to large propeller systems rated at several MW. We can supply individual starting equipment and/or complete motor control centers that are fully certified and include direct start, Y-D start, soft start, and frequency converters in power ranges from 4 kW/1,000 V up to 3 MW/11.4 kV.


All equipment can be classified by: DNVGL, BV, LRS, ABS, NKI, and CCS.

Soft Starts

A soft starter is an electronic starting device that limits power consumption during startup and gradually increases the voltage until the operating voltage is reached. The time this takes may vary depending on the application’s requirements. A variable frequency drive (VFD) is an electronic control function that regulates an electric motor by adjusting both the frequency and voltage of the power supply. It can also control ramp-up and ramp-down during start and stop sequences. Elektromontage represents the soft starter manufacturer Solcon in Sweden.

A soft starter reduces wear on the transmission, shafts, and bearings at every start-up. Wear is significantly reduced, especially on large starting equipment where a substantial mass often needs to be set in motion at the moment of startup.

Maintenance costs are often drastically reduced, and equipment availability increases with a soft starter. Solcon has an extensive track record of advanced soft starter installations for both low- and high-voltage systems.

Pump Starter 

A simple pump starter is a feature that activates pumps in a simple and reliable manner without overloading the electrical grid. This can be achieved through methods such as Y/D starting, soft starting, or frequency conversion, depending on the customer’s preferences. In larger applications, such as in marine engines, the challenges are somewhat more restrictive. Here, careful design is required to start the machinery as energy-efficiently and weight-optimized as possible, taking into account the generator, the electrical system, and the weight limitations on board.

Automatic Transformer Starter

An autotransformer starter is a proven starting method that involves large AC contactors and a temporary increase in voltage in the motor circuit. This is intended to minimize current spikes during startup and acceleration. This method is often more cost-effective than electronic alternatives.

Experience and Capacity

All of these variations in starting systems, along with classification requirements, specific national requirements, and the harsh environment in which the application will operate, influence the design process. Elektromontage has served as a supplier for a wide range of starting systems over the years and is therefore a reliable partner in these matters. Starting systems from Elektromontage have been supplied for a wide range of marine applications, both civilian and military, where high demands have been placed on design and execution.

We can supply power ranging from 4 kW up to 1,750 kW at 230–1,000 V and 0.2 MWA to 21.8 MWA at 2.3–13.8 kW. 

Frequently Asked Questions About Starter Kits

Here you'll find answers to frequently asked questions about starter kits

What is the difference between a soft starter and a variable-frequency drive?

The main difference between a soft starter and a variable frequency drive (VFD) lies in how they control the motor. A soft starter gradually increases the voltage at startup, thereby reducing the starting current and starting torque, which protects the motor during startup and shutdown. It is best suited for applications where the motor runs at a fixed speed and speed control is not required.

A variable frequency drive (VFD), on the other hand, provides full control over the motor’s speed and torque by regulating the frequency and voltage of the power supply. This makes it suitable for applications where the speed needs to be adjusted with high precision. Variable frequency drives offer greater flexibility but are typically more complex and costly than soft starters.

How reliable is a soft starter?

Soft starters are known for their high reliability thanks to their simple design and operation. They are a cost-effective solution for applications that require motors to start smoothly, without advanced speed control. The simple design means fewer potential sources of failure, making soft starters a reliable option for systems where motor speed control is not required. For applications with a fixed speed, soft starters are durable, efficient, and economical, and they can often be used for many years with minimal maintenance.

What is the difference between a soft start and a direct start?

A direct start connects the motor to full voltage immediately upon startup, resulting in a high starting current and a sharp increase in torque. The sudden load can strain the electrical circuits and place mechanical stress on the motor, which over time can lead to wear and tear.

A soft starter, on the other hand, gradually increases the voltage to the motor, which limits the starting current and starting torque and provides a smoother, more controlled start. This helps prevent overloading of the electrical circuits, extends the motor’s service life, and is particularly useful in applications where the equipment is frequently started and stopped.

What is a pump starter?

A pump starter is a starting device specifically designed to safely start and control pump motors, and is often used in industry and agriculture in applications such as wastewater management, water treatment, and irrigation.

Pump starters protect the motor by limiting the starting current and ensure smooth motor operation, often with overload protection tailored to the specific requirements of pump operation. Pump starters are designed to protect the motor from damage caused by high starting currents, extend its service life, and increase operational reliability without the need for additional fuses.

Why do pumps need starting equipment?

Pumps require starting equipment to handle the high starting current and starting torque that occur when a pump motor starts, which could otherwise cause damage to the motor or the electrical system.

The starting equipment helps regulate the initial voltage to the motor, preventing sudden current surges that could overload electrical circuits or cause mechanical stress. Many pump starters also feature protective functions that detect voltage fluctuations or electrical faults and can automatically shut off the pump to prevent damage. This protection is essential for ensuring the reliable operation of a pump system and for extending the equipment’s service life, especially in demanding applications such as water treatment and irrigation.

What is the purpose of an autotransformer (energy-saving transformer)?

The primary purpose of an autotransformer is to efficiently adjust voltage levels in industrial and commercial applications. Unlike conventional transformers, autotransformers have a single winding that serves as both the primary and secondary windings, making them more compact and cost-effective. They are often used to step up or step down the voltage on equipment such as motors, compressors, and CNC machines, where precise voltage adjustment is critical. This design provides a stable power supply with low energy losses and costs, making autotransformers suitable for applications that require reliable voltage regulation.

How does an auto-transformer starter work?

An autotransformer starter reduces the voltage to a motor during startup, which limits the starting current and provides the motor with a smoother start. When the motor is started, the autotransformer starter reduces the voltage to limit the initial current, thereby preventing sudden current surges. As the motor accelerates, it gradually transitions to full voltage, completing the starting process. Autotransformer starters are often used in applications where smooth acceleration is needed, and where the more advanced control features of a variable frequency drive (VFD) are not required. They are particularly useful for motors that require high starting torque.

What is the difference between a star-delta starter and a soft starter?

The main difference between star-delta starters and soft starters lies in how flexibly they can control and adapt the starting process to the motor’s load. Star-delta starters first connect the motor windings in a star configuration and then switch to a delta configuration once the motor has reached a certain speed. This method reduces the starting current but offers limited control over the starting process, and the starting torque cannot be adjusted to specific load characteristics. A soft starter, on the other hand, provides a smoother and more adaptable motor start by gradually increasing the voltage to the motor, which reduces mechanical stress and starting current through a more controlled starting process. Soft starters offer greater flexibility in controlling starting torque and are therefore well-suited for applications with varying loads or where equipment is frequently started and stopped.